Igor Lazbin
- Registered on: 11/13/2017
 - Last connection: 06/22/2020
 
Issues
- Assigned issues: 8
 - Reported issues: 10
 
Projects
Activity
06/22/2020
- 11:46 AM LTES Problem Report #31: Telemetry dropout following velocity change command
 - Cause
While trying to reproduce this scenario in simulation, I noticed that the triangular ramp responsible for gene... - 11:45 AM LTES Feature #32: Intermediate-size science frames are created following scan period change
 - Due to scan change being applied on positive zero crossing. Change needed to apply in either direction
 - 11:43 AM LTES Support #34 (New): Update Power-on defaults
 - Update parameters for servo optimization, default velocity, cal flag duration, fault protection.
 - 11:42 AM LTES Support #33 (New): Cal flag at the end of acquisitions
 - Cal flag should open at the end of all acquisitions. Cal flag should not change state as a result of "abort" command.
 - 11:40 AM LTES Feature #32 (New): Intermediate-size science frames are created following scan period change
 - One or two intermediate-size science frames are created when changing scan period. One is expected.
 - 11:38 AM LTES Problem Report #31 (New): Telemetry dropout following velocity change command
 - While attempting to change servo velocity from .333 mm/sec to .2806mm/sec, a loss of telemetry was observed. This wa...
 
04/08/2019
- 10:00 AM EMIRS Bug #25 (Resolved): OS Drift during pointing mirror rotation
 - 09:59 AM EMIRS Bug #24 (Resolved): Extra Data Packets
 - 09:59 AM EMIRS Bug #23 (Resolved): Mirror rotation
 
01/28/2019
Also available in: Atom