Project

General

Profile

Support #16

Cmd and Tlm Spec Updates

Added by Greg Mathis over 6 years ago. Updated over 6 years ago.

Status:
Closed
Priority:
Normal
Assignee:
Start date:
03/20/2018
Due date:
% Done:

0%

Estimated time:

Description

In the Command and Telemetry Spec, the description for telemetry item "Configuration Status 1", shows the following:

Bit 0: Linear Motor LED 1 Pwr Status, 0 = Off, 1 = On
Bit 1: Linear Motor LED 2 Pwr Status, 0 = Off, 1 = On
Bit 2: Stepper Motor Coarse LED 1 Pwr Status, 0 = Off, 1 = On
Bit 3: Stepper Motor Coarse LED 2 Pwr Status, 0 = Off, 1 = On
Bit 4: Stepper Motor Fine LED 1 Pwr Status, 0 = Off, 1 = On
Bit 5: Stepper Motor Fine LED 2 Pwr Status, 0 = Off, 1 = On

But I think it should be:

Bit 0: Linear Motor LED 2 Pwr Status, 0 = Off, 1 = On
Bit 1: Linear Motor LED 1 Pwr Status, 0 = Off, 1 = On
Bit 2: Stepper Motor Coarse LED 2 Pwr Status, 0 = Off, 1 = On
Bit 3: Stepper Motor Coarse LED 1 Pwr Status, 0 = Off, 1 = On
Bit 4: Stepper Motor Fine LED 2 Pwr Status, 0 = Off, 1 = On
Bit 5: Stepper Motor Fine LED 1 Pwr Status, 0 = Off, 1 = On

History

#1 Updated by Greg Mathis over 6 years ago

  • Status changed from New to Closed

This was updated in the Rev A release of the Command and Telemetry Specification (EMIRS Doc # 401009, AZST Doc # DSPC100062)